Halogen-free, flame-retardant MPPE cable
UL21503, UL21504, UL multi-core halogen-free, flame-retardant, MPPE cable
Conductor stranded tinned copper wire, PE insulation, aluminum foil shield (optional), ground wire (optional), braided shield (optional), MPPE sheath
Printing
E254881 UL 1 AWM STYLE 21503 AWG NO. 105℃ 30V VW-1
CUL c1 AWM I/II A/B 105℃ 30V FT1 -LF- -HF- ELETECK
product manual
-Rated temperature: 105℃
-Rated voltage: 30V
-Executive standard: UL758, UL1581, CSA C22.2 No.210
-Passed VW-1, FT1 vertical combustion test
Belongs to ULAWM wire, UL758 electronic wire, halogen-free multi-core shielded wire, equipment internal wire, external wire, connecting wire signal wire, control wire, 30V wire
UL21504 halogen-free multi-core shielded wire
Printing
E254881 UL AWM STYLE 21504 AWG NO. 105℃ 30V VW-1
cUL AWM I/II A/B 105℃ 30V FT1 -LF- -HF- ELETECK
product manual
-Rated temperature: 105℃
-Rated voltage: 30V
-Executive standard: UL758, UL1581, CSA C22.2 No.210
-Passed VW-1, FT1 vertical combustion test
UL21503 halogen-free multi-core shielded wire
Conductor stranded tinned copper wire, PE insulation, aluminum foil shield (optional), ground wire (optional), braided shield (optional), MPPE sheath
Printing
E254881 UL 1 AWM STYLE 21503 AWG NO. 105℃ 30V VW-1
CUL c1 AWM I/II A/B 105℃ 30V FT1 -LF- -HF- ELETECK
product manual
-Rated temperature: 105℃
-Rated voltage: 30V
-Executive standard: UL758, UL1581, CSA C22.2 No.210
-Passed VW-1, FT1 vertical combustion test
Belongs to ULAWM wire, UL758 electronic wire, halogen-free multi-core shielded wire, equipment internal wire, external wire, connecting wire signal wire, control wire, 30V wire
conductor
|
insulation
|
shield
|
Insulation sheath
|
20℃
Maximum resistance (Ω/km) |
|||
Number of cores
|
Gauge line
|
Wire number / wire diameter
|
Thickness (mm)
|
Outer diameter (mm)
|
Wire number/wire diameter
|
Outer diameter (mm)
|
|
3
|
28
|
7/0.127
|
0.26
|
0.90
|
16/4/0.10
|
3.60
|
239
|
4
|
28
|
7/0.127
|
0.26
|
0.90
|
16/4/0.12
|
4.40
|
239
|
5
|
28
|
7/0.127
|
0.26
|
0.90
|
16/4/0.12
|
4.60
|
239
|
6
|
28
|
7/0.127
|
0.26
|
0.90
|
16/5/0.12
|
4.60
|
239
|
8
|
28
|
7/0.127
|
0.26
|
0.90
|
16/7/0.12
|
4.60
|
239
|
3
|
26
|
7/0.16
|
0.26
|
1.00
|
16/5/0.12
|
4.60
|
150
|
6
|
26
|
7/0.16
|
0.26
|
1.00
|
16/6/0.12
|
5.00
|
150
|
9
|
26
|
7/0.16
|
0.26
|
1.00
|
16/6/0.12
|
5.90
|
150
|
5
|
24
|
11/0.16
|
0.27
|
1.15
|
16/6/0.12
|
5.50
|
94.2
|
UL21504 halogen-free multi-core shielded wire
Printing
E254881 UL AWM STYLE 21504 AWG NO. 105℃ 30V VW-1
cUL AWM I/II A/B 105℃ 30V FT1 -LF- -HF- ELETECK
product manual
-Rated temperature: 105℃
-Rated voltage: 30V
-Executive standard: UL758, UL1581, CSA C22.2 No.210
-Passed VW-1, FT1 vertical combustion test
conductor
|
insulation
|
shield
|
Insulation sheath
|
20℃
Maximum resistance (Ω/km) |
|||
Number of cores
|
Gauge line
|
Wire number / wire diameter
|
Thickness (mm)
|
Outer diameter (mm)
|
Wire number/wire diameter
|
Outer diameter (mm)
|
|
3
|
28
|
7/0.127
|
0.26
|
0.90
|
16/4/0.10
|
3.60
|
239
|
4
|
28
|
7/0.127
|
0.26
|
0.90
|
16/4/0.12
|
4.40
|
239
|
5
|
28
|
7/0.127
|
0.26
|
0.90
|
16/4/0.12
|
4.60
|
239
|
6
|
28
|
7/0.127
|
0.26
|
0.90
|
16/5/0.12
|
4.60
|
239
|
8
|
28
|
7/0.127
|
0.26
|
0.90
|
16/7/0.12
|
4.60
|
239
|
3
|
26
|
7/0.16
|
0.26
|
1.00
|
16/5/0.12
|
4.60
|
150
|
6
|
26
|
7/0.16
|
0.26
|
1.00
|
16/6/0.12
|
5.00
|
150
|
9
|
26
|
7/0.16
|
0.26
|
1.00
|
16/6/0.12
|
5.90
|
150
|
5
|
24
|
11/0.16
|
0.27
|
1.15
|
16/6/0.12
|
5.50
|
94.2
|